UVCS MISSION LOG ---------------- Date: 03 July 2003 ----- Last revision: 08 July 2003 (Wu) -------------- File Name: 2003.07.05.a.log ----------- Compiled by: R. Wu ------------ UVCS Activity: UVCS in Modified Hard Safe Configuration -------------- SOHO Activity: -------------- EOF Staff: M. Uzzo: Lead Scientist ---------- Y.-K. Ko R. Wu Command file: No Commanding Activity: --------- 1) UVCS in Modified Hard Safe Configuration Sequence: None SCI_SPEC: Following completion of Coronal Jets Study for 24 June 2003, UVCS is placed into a modified Hard Safe configuration in preparation for the SOHO HGA Blackout Period. Detector High Voltage is then ramped down and turned off, OVI Slit is closed from 150 microns to 100 microns, instrument is rolled to the nominal East (35156 Engineering Units), and Mirror / Occulter is moved to 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is also closed 708 steps, Internal Mirror / Occulter Heater set to 100% duty cycle. Internal Spectrometer Heater is not turned on. In addition to "traditional" Hard Safe configuration, UVCS Detector Power is turned off. FOT Monitoring UVCS using ESR Limit Table, TSU Substitution Heater (Circuit #84) and set duty cycle to 60%. Expected Limit Violation sheets submitted to FOT via SOC for any expected limit violations during this time. FOT told to ignore USDR = MOVING condition, but to notify UVCS representative should this condition change for more than two minutes. Experiment Offpoint, and ESR Flags are disabled. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2003.06.25.18:44 end: 2003.07.08.13:42 ONUMs = 20026 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 90 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 100 um - LYA GRTPOS: 128000 - OVI GRTPOS: 192000 - LYA HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - LYA mask: LYA_93_1sec in slot 2 - OVI mask: OVI_Syn_192 in slot 2 Fits Files: