UVCS MISSION LOG ---------------- Date: 19 August 2005 ----- Last revision: 07 September 2005 (Wu) -------------- File Name: 2005.09.11.a.log ---------- Compiled by: M. Uzzo, R. Wu ------------ UVCS Activity: UVCS in Modified Hard Safe configuration for Keyhole -------------- SOHO Activity: -------------- EOF Staff: R. Wu: Lead Scientist ---------- Y.-K. Ko M. Uzzo Command file: No Commanding Activity: --------- 1) UVCS in Modified Hard Safe Configuration Sequence: None SCI_SPEC: Following completion of Science Observations, UVCS is placed into a modified Hard Safe configuration in preparation for the SOHO Keyhole Period. OVI Slit is set to 100 microns, instrument is rolled to the nominal East (35156 Engineering Units). Detector High Voltage is ramped down and then turned off, Mirror is moved to 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is also closed 708 steps, Internal Mirror / Occulter Heater set to 100% duty cycle. Internal Spectrometer Heater is not turned on. In addition to "traditional" Hard Safe configuration, all UVCS detectors are powered off. FOT use ESR Limit Table, TSU Substitution Heater (Circuit #84) powered on, using duty cycle of 50%. Experiment Offpoint, and ESR Flags disabled for Keyhole. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2005.09.11.16:00 end: 2005.09.12.16:00 ONUMs = 48677 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 90 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 100 um - LYA GRTPOS: 128000 - OVI GRTPOS: 229000 - LYA HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - OVI mask: OVI_Syn_230 in slot 1 Fits Files: