UVCS MISSION LOG ---------------- Date: 27 November 2005 ----- Last revision: 28 November 2005 (Wu) -------------- File Name: 2005.11.27.a.log ---------- Compiled by: M. Uzzo ------------ UVCS Activity: Load and Start Radiometric Calibration using Star Omega -------------- Scorpionis for 27 November 2005 Ramp Down and Turn Off LYA HV and Detector Power Turn On OVI Detector Power Conduct OVI Stimulus Pulse Test Turn On and Ramp Up OVI HV Load and Start OVI Synoptic for 27 - 28 November 2005 Load Ulysses-SOHO Quadrature for 28 - 30 November 2005 Load OVI Synoptic for 30 November 2005 SOHO Activity: -------------- EOF Staff: L. Gardner: Lead Scientist ---------- M. Uzzo: Commander, Planner Command file: 05.11.27.18:06:55.cmd.log Activity: --------- 1) Spectral Studies Using Omega Scorpionis Sequence: Manual, TakeUV_TxN.tcl (120 sec.) SCI_SPEC: Star Observations OBS_PROG: Primary: Calibration Sub Obj: Spectral Coverage SCI_OBJ: Primary: Calibration...Radiometric Calibration Sub Obj: Celetial Targets...Star OBJ: Star...Omega Sco CMP_NAME: CMP_NUM: Duration: start: 2005.11.27.18:38 end: 2005.11.27.19:40 ONUMs = 21983 ( exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 270 Degrees (2378) - Mirror/Occulter: 7.54, 7.64 Ro Occulter widths: 29.6mm (34108) 49.0mm (28382) - LYA Slits: 100 um - OVI Slits: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 176000 - LYA MCP Voltage: 195 - OVI MCP Voltage: 0 - LYA DETECTOR POWERED ON - OVI DETECTOR POWERED OFF - LYA mask: RStar_LYA in slot 1 Fits Files: q05.11.27.18:23:01.lya.dat 2) OVI Stimulus Pulse Test Sequence: Manual SCI_SPEC: To confirm that the OVI detector is functioning nominally, Stimulus Pulse enabled for the exposures with High Voltage Power Supply powered off. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2005.11.27.19:52 end: 2005.11.27.19:56 ONUMs = 21984 (2 exps) Instrument configuration: - Pointing: Sun Center - Spacecraft Roll: 0 Degrees - Roll: 144 Degrees (45000) - Mirror/Occulter: 1.75 Ro 1.5 mm overocculting - LYA Slit: 150 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 176000 - LYA MCP Voltage: 0 - OVI MCP Voltage: 0 - OVI DETECTOR POWERED ON - LYA DETECTOR POWERED OFF - LYA mask: msk_000303_OVI in slot 3 Fits Files: q05.11.27.19:49:06.ovi.dat 3) OVI Synoptic Sequence Load and Start Sequence: SynopticD:Start SCI_SPEC: Synoptic studies. VLD & LYA HV & Power off / OVI voltage at 200. OBS_PROG: Synoptic SCI_OBJ: Synoptic OBJ: Entire Corona CMP_NAME: CMP_NUM: Duration: start: 2005.11.27.20:11 end: 2005.11.28.10:24 ONUMs = 49040 (49 exps) 49041 (49 exps) 49042 (47 exps) 49043 (49 exps) 49044 (49 exps) 49045 (49 exps) 49046 (47 exps) 49047 (49 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: W: os, NW: os, N: oc, NE: os, E: os, SE: os, S: oc, SW: os - Mirror/Occulter: ls: 3.00, 2.50, 2.10, 1.90, 1.75, 1.60 Ro lc: 2.10, 1.90, 1.75, 1.60 Ro os: 3.00, 2.10, 1.90, 1.75, 1.60 Ro oc: 1.90, 1.75, 1.60 Ro ms: 2.10, 1.75, 1.60 Ro mc: 1.90, 1.75, 1.60 Ro 1.5 mm overocculting (1.60 Ro) 2.0 mm overocculting (1.75, 1.90, 2.10, 2.50, 3.00 Ro) - LYA Slits: 100 um - OVI Slits: 150 um (LyA Synoptic) 200 um (OVI, and Mini Synoptic) - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 (LyA Synoptic) 229000 (OVI, and Mini Synoptic) - OVI MCP Voltage: 200 - OVI mask: OVI_Syn_188 in slot 2 (LyA Synoptic) OVI_Syn_230 in slot 1 (OVI, and Mini Synoptic) Fits Files: z05.11.27.20:10:17.ovi.dat z05.11.27.21:58:57.ovi.dat z05.11.27.23:47:37.ovi.dat z05.11.28.01:31:04.ovi.dat z05.11.28.03:19:44.ovi.dat z05.11.28.05:08:24.ovi.dat z05.11.28.06:57:04.ovi.dat z05.11.28.08:40:31.ovi.dat